Rural Living       Agriculture       Off-Grid       Rail & Mass Transit       Fire & Rescue        Vehicles
Roof De-icing       OEM/R&D Services       Municipal       Commercial       Industrial
De-Icing & freeze protection for:
  • Roofs, Gutters, Down Spouts
  • Ice and snow melt systems
Paladin® for Roof
Paladin is an award winning cable that can be used for roof and gutter de-icing and employs the unique performance and operating characteristics of self-regulating heating cable technology. Paladin can be used in conjunction with EDGE-CUTTER channel flashings or in the conventional serpentine configuration using roof clips. Paladin can be used in a variety of applications including, cottages, homes, resorts and farms. Snow sensors, thermostats, timers or other approved devices can be added to the system for increased energy efficiency.

Product Application
Paladin is an exceptional freeze protection system for roof-de-icing and can be used on many different roof types and applications. Roof edge ice build-up, eave icing, icicles and ice dams can all be easily eliminated. Whether a Paladin is used in the conventional serpentine configuration or in conjunction with EDGE-CUTTER it is the most reliable, energy efficient system on the market. In applications where the Paladin systems are not suitable, installations may be customized using Heat-Line Cut-to-Length heating cables.

Specifications
  • cCSAus approved (Canada and USA)
  • 120 Volt systems - 5watt /ft. at 50°F maximum length of 120 ft.
  • 240 Volt systems - 5watt/ft. at 50°F maximum length 240 ft.
  • 27 milliamp ground fault circuit interrupter plug-in device
Benefits of Paladin
  • cCSAus approved (Canada and USA)
  • 5 year limited warranty
  • Most reliable and energy efficient system on the market
  • Can be easily installed on the roof edge with EDGE-CUTTER
  • Can be easily installed on the roof edge in the serpentine configuration using roof clips
  • Will not over heat
  • Snow sensors, thermostats, timers or other approved devices can be added to the system for increased energy efficiency
  • Available in lengths from 10' to 240' (for longer length see Cut-to-Length)
  • Ground fault protection is integral to the system.
  • Simply plugs into a 120V or 240V receptacle. No extra electrical work is required.
  • No other product combines these features and offers the reliability and flexibility of Paladin
Included in a Paladin system
  • Factory finished, self-regulating heating cable set
  • 27 milliamp GFCI (ground fault circuit interrupter) electrical plug in device
  • ½" polyethylene cable guards
  • 8" cable ties
Below are several downloadable documents about Paladin for Roof:
Paladin for Roof Brochure
Installation Guide 1


Edge-Cutter®
EDGE-CUTTER channel flashings are designed to prevent ice build-up, icicles, or ice dams on the roof edge. It can be used with various roofing products such as asphalt shingles, aluminum, steel and even slate. Each 4' aluminum flashing is feathered and has a channel to accommodate the self-regulating heating cable. The flashing is installed under the leading roof edge using screws, nails, or adhesives. The Paladin system or Heat-Line Cut-to-Length self-regulating heating cable is then installed within the channel and a cap secures it in place.
USE ONLY APPROVED SELF-REGULATING HEATING CABLES.
NOT FOR USE WITH CONSTANT WATTAGE HEATING CABLES!

Product Application
The EDGE-CUTTER flashing can be used on low-pitched roofs, fascia, valleys, and drip edges. If a metal roof is present, the EDGE-CUTTER channel flashing should be ordered with a 6 mil urethane membrane factory installed directly onto the flashing to prevent galvanic oxidation between dissimilar metals. Flat and angled EDGE-CUTTER channel flashings are available to suit different application requirements.

In areas where EDGE-CUTTER channel flashings are not required, the Paladin heating cable can simply be mounted with clips on the roof surface in the conventional serpentine configuration.

Benefits of EDGE-CUTTER
  • 4' feathered aluminum flashing complete with cap
  • Fast, easy installation
  • Can be used under metal, asphalt and slate roof
  • For new or existing roofs
  • Aesthetically pleasing
  • Many different uses
  • Can be used with Paladin heating cable sets
  • Can be used with Heat-Line cut-to-length heating cables*
  • Membrane available
* Approved roof and gutter powered connection kits required.

EDGE-CUTTER often requires consultation as there are large application variables. Heat-Line provides technical support for these situations.

Below are several downloadable documents about the EDGE-CUTTER:
Edge-Cutter Brochure
Installation Guide 1


Thawing Built Up Snow on a Roof
Paladin® System Used for Temporary Emergency Relief from Snow and Ice Build-up

Conceptual Drawing
This instruction is offered as a TEMPORARY solution to a roof leak emergency. After clearing the emergency ice build-up the system must be reinstallaed in accordance to the manufacturer's instruction provided with the product.

This concept is for use with Paladin self regulating heating cables only. DO NOT use with constant wattage heaters. Ground-fault protection must be used.

CAUTION: Icy roofs can be dangerous.





welcome ~  why Heat-Line ~  product search ~  news & events ~  trades people ~  request ~  faq ~  contact ~  site map
Heat-Line ~  Retro-Line ~  Paladin for Pipe ~  EXT5R Series ~  EXT3T Series ~  CARAPACE ~  Kompensator
Cut-to-Length ~  Paladin for Roof ~  EDGE-CUTTER ~  ArcticVent ~  Accessories

Contents and product concepts are copyright protected - all rights reserved.
No duplication without express permission of Heat-Line a Division of Christopher MacLean Ltd.